CCLZT - BATTERY ELECTROLYTE (ACID GEL)

  • MSDS: CCLZT
  • Manufacturer: POWER SONIC CORP
  • Product Name: BATTERY ELECTROLYTE (ACID GEL)
  • National Stock Number: 6135-01-292-1071
Product Identification

Product ID:BATTERY ELECTROLYTE (ACID GEL)
MSDS Date:07/05/1992
FSC:6135
NIIN:01-292-1071
MSDS Number: CCLZT

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 415-364-5001

Info Phone: 415-364-5001/FAX415-366-3862

Cage: 56309

Contractor
POWER-SONIC CORP
5242 REDWOOD CITY, CA 94063-3929 US

Telephone: 650-364-5001

Cage: 56309

Ingredients

SULFURIC ACID (SARA 302/313) (CERCLA)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 39.1%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3/3 STEL; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NOT GIVEN
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:BATTERY NOT HAZ UNDER NORMAL
CONDITIONS TIL BROKEN.ELECTROLYTE CAUSES:SEV EYE/SKIN BURNS/CORNEA
DAMAGE/BLINDESS.SEV SKIN IRRIT/ULCERATION.BRONCHIAL
MEMBRANES/TUBES,NOSE/THRO INFLAMM.SEV BURNS/ULCERATI ON OF
MOU/THRO/ESOPH/STOMA;KIDNEY&INTEST DAMAGE.TEETH ERROSION.CONJ/RESP
INFECT/EMPHY/DIGEST DISTUR.LEAD POISONING.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:CONCENTRATION AS LOW AS 5MG/M3 CAN CAUSE
COUGH/INCREASED RESPIRATORY RATE & IMPAIRED VENTILARY CAPACITY.
STINGING OF SKIN/BURNING SENSATION CAUSED BY DROPLETS/MIST. EYE
IRRITATION OCCURS @ CONC OF 1.1 -2.4MG/M3. TEETH MAY BECOME
DISCOLORED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. WASH OUT
MOUTH. GIVE MILK WITH EGG WHITES OR VEGETABLE OIL. GET MEDICAL
ATTENTION.

Fire Fighting

Flash Point:NOT COMBUSTIBLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:FOR FIRES IN AREA: DRY CHEMICAL, CARBON DIOXIDE,
WATER FOG, WATER.
Fire Fighting Procedures:WEAR NIOSH APPROVED SELF CONTAINED BREATHING
APPARATUS & FULL-COVER SULFURIC ACID RESISTANT CLOTHING.
Unusual Fire/Explosion Hazard:ACID REACTS VIOLENTLY W/METALS,NITRATES,
CHLORATES,CARBIDES,FULMINATES,PICRATES,& OTHER ORGANIC MATLS.
HYDROGEN GAS RESULTS FROM ACID/METAL CONTACT DIL IN WATER

Accidental Release

Spill Release Procedures:VENTILATED AREA. EVACUATE AREA. WEAR PROPER
PERSONAL PROTECTIVE EQUIPMENT. ABSORB LIQUIDS FROM CELL WITH SODIUM
BICARBONATE OR SLAKED LIME.
Neutralizing Agent:LIME, SODA ASH, SODIUM BICARBONATE

Handling

Handling and Storage Precautions:STORE COOL,DRY,VENTILATED AREA
PROTECTED FROM SEVERE WEATHER. KEEP AWAY FROM FIRE/SPARKS/ HEAT.
Other Precautions:ELECTROLYTE WILL ATTACK SOME FORMS OF PLASTICS,
RUBBER, OR COATINGS THAT ARE NOT ACID-RESISTANT.

Exposure Controls

Respiratory Protection:NOT REQUIRED UNDER NORMAL CONDITIONS. WHEN
CONCENTRATIONS OF SULFURIC ACID IN AN AREA MAY EXCEED PEL, USE
NIOSH- APPROVED, FITTED, FULL FACE RESPIRATOR WITH APPROPRIATE
FILTER OR SELF- CONTAINED BREAT HING APPARATUS.
Ventilation:USE IN WELL VENTILATED AREA W/NO CROSS DRAFTS. VENTILATION
COMPONENTS MUST BE ACID & EXPLOSION RESISTANT.
Protective Gloves:ACID RESISTANT RUBBER/PLASTIC.
Eye Protection:ACID-RESISTANT GOGGLES W/FACE SHIELD.
Other Protective Equipment:GLOVES SHOULD HAVE ELBOW-LENGTH GAUNTLET &
ROLLED-OVER CUFF. ACID-RESISTANT APRON & BOOTS. EMERGENCY EYEWASH &
SHOWER.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
BATTERY NOT HAZARDOUS UNDER NORMAL CONDITIONS;HOWEVER, IF BROKEN
ELECTROLYTE IS HAZARDOUS. THIS ENTRY FOR BATTERY ELECTROLYTE (ACID
GEL).

Chemical Properties

HCC:C1
Boiling Pt:B.P. Text:237F,114C
Melt/Freeze Pt:M.P/F.P Text:-94F,-70C
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres:9.95
Vapor Density:>1
Spec Gravity:1.280
pH:< 7
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS GEL, WITH SHARP, PENETRATING, PUNGENT
ODOR.
Percent Volatiles by Volume:0 @70F

Stability

Stability Indicator/Materials to Avoid:YES
COMBUSTIBLES, ORGANICS, STRONG REDUCING AGENTS, METALS, SULFUR TRIOXIDE
GAS, STRONG OXIDIZERS, WATER, METALS.
Stability Condition to Avoid:CONTACT W/COMBUSTIBLES & ORGANICS MAY
CAUSE FIRE & EXPLOSION. CONTACT W/METALS PRODUCES TOXIC SULFUR
DIOXIDE & HYGROGEN.
Hazardous Decomposition Products:SULFUR TRIOXIDE & DIOXIDE, SULFURIC
ACID FUMES, CO, HYDROGEN SULFIDE, HEAT.

Disposal

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.